Abstract [eng] |
The final master thesis presents technical analysis of low-energy residential building in Vilnius, Lithuania. Building has low temperature floor heating, mechanical ventilation with heat recovery unit and hot water preparation with buffer tank systems. Using “CASAnova” software is calculated fourth energy balances of building according fourth different heat transfer coefficients of the walls. All heating and cooling energy demand of a building is generated from the ground. It is made by using a heat pump with single borehole. A calculation of borehole sizing is made with “EED” software. Two energy saving technologies are analysed for a building. The first idea is to reduce heat energy consumption of hot water preparation. There is calculated benefit of waste water heat recovery heat exchanger which function is to pre-heat hot water using waste water from the shower. Second idea is to reduce heat energy consumption for fresh air heating in air handling unit. There is calculated benefit of earth-to-air heat exchanger using “GAEA” software. Final result of all calculations shows influence of heat transfer coefficient and energy saving technologies to building annual energy balance and depth of borehole. Economic benefit of using energy saving technologies is calculated. Structure: introduction, 6 chapters, conclusions and suggestions, references. Thesis consists of 64 p. of text, 41 figures, 14 tables and 31 bibliographical entries. |